Trial protocol

Cement Grinding Aid Mill-Trial Protocol

Use this protocol to compare grinding-aid performance without mixing process gains with changes in cement quality.

Published by CementGrindingAid.com · Last reviewed 24 July 2026 · How this content is produced

1. Define the decision before dosing

State the primary objective—throughput, kWh/t, fineness, residue, handling or strength—and the quality limits that must remain equivalent. Define the measurement boundary for electrical energy.

2. Record a stable untreated baseline

AreaMinimum data
FeedClinker, gypsum and additions; moisture; feed rate.
MillMill type, circuit, motor power, t/h, kWh/t, temperatures and relevant control settings.
Separator / transportSeparator speed, airflow or differential pressure, recirculating load where available.
CementBlaine, residue, PSD where available, water demand, setting and 1/3/7/28-day strength.

3. Calibrate dosing

Confirm the product grade, current density and pump/feeder calibration. For liquid product, verify actual collected mass or volume over a timed interval. Use the dosage calculator to translate g/t into kg/h.

4. Run controlled dosage steps

  1. Change only the grinding-aid dosage unless the test plan explicitly requires another variable.
  2. Allow sufficient residence and circuit-stabilization time.
  3. Record continuous process data and time-match cement samples.
  4. Do not accept higher t/h if fineness, residue or strength falls outside the agreed limit.
  5. Check for overdosing symptoms and dosing-line stability.

5. Compare economics without double counting

Calculate chemical cost, measured energy benefit and any genuinely saleable extra output separately. Do not count a throughput increase as revenue unless the plant can sell the additional cement and has no downstream constraint.

6. Trial record to retain

  • Product name, batch and COA
  • Dosage steps and calibration record
  • Raw material and cement composition
  • Timestamped process data
  • QC samples and test results
  • Operating observations and deviations
  • Approved conclusion and next action

Standards & method references

The applicable standard, edition and local regulatory requirement must be confirmed for each project. A reference does not claim product compliance.

Review your cement and mill baseline

Send cement type, mill system, output, kWh/t, fineness, strength and target.

Contact Tony